Reset Risk Acknowledgment Message Fields

Response to a Reset Risk message request.

Table 1. Reset Risk Acknowledgment Message Fields
FieldOffsetLengthData TypeDescription
StartOfMessage02BinaryMust be 0xBA 0xBA.
MessageLength22BinaryNumber of bytes for the message, including this field but not including the two bytes for the StartOfMessage field.
MessageType41Binary 0x57
MatchingUnit51BinaryUnsequenced application message. Matching unit will be set to 0.
SequenceNumber64BinaryUnsequenced application message. Sequence number will be set to 0.
RiskStatusID1016TextUnique identifier for this Reset Risk request. Response message will have this corresponding identifier.
RiskResetResult261Text
  • <space> = Ignored; exceeds 1 reset per 100 milliseconds
  • C = Rejected; exceeds Custom Group ID limit
  • D = Rejected; automatic risk resets are disabled
  • E = Rejected; empty ResetRisk field
  • F = Rejected; exceeds firm reset limit
  • I = Rejected; incorrect data center
  • M = Rejected; invalid matching unit
  • S = Rejected; exceeds risk root reset limit
  • U = Rejected; invalid RiskRoot
  • Y = Success
  • c = Rejected; invalid EFID/ClearingFirm
  • y = Rejected; in replay
  • Additional reject values may be added in the future with no notice.
Table 2. Risk Reset Acknowledgment Message Example
Field NameHexadecimalNotes
StartOfMessage BA BAStart of message bytes.
MessageLength 19 0025 bytes
MessageType 57 Risk Reset Acknowledgement
MatchingUnit 00Unsequenced Message, unit = 0
SequenceNumber 00 00 00 00Unsequenced Message, sequence = 0
RiskStatusID 41 42 43 31 32 33 00 00 00 00 00 00 00 00 00 00ABC123
RiskResetResult 00 Y = Success