Client Heartbeat Message Fields

See Heartbeats for more information about heartbeats and the session level protocol.

Table 1. Client Heartbeat Message Fields
FieldOffsetLengthData TypeDescription
StartOfMessage02BinaryMust be 0xBA 0xBA.
MessageLength22BinaryNumber of bytes for the message, including this field but not including the two bytes for the StartOfMessage field.
MessageType41Binary 0x03
MatchingUnit51BinaryAlways 0 for inbound (Member to Cboe) messages.
SequenceNumber64BinaryAlways 0 for session level messages.
Table 2. Client Heartbeat Message Example
Field NameHexadecimalNotes
StartOfMessage BA BAStart of message bytes.
MessageLength 08 008 bytes
MessageType 03 Client Heartbeat
MatchingUnit 00Always 0 for inbound messages
SequenceNumber 00 00 00 00Always 0 for session level messages